Installation and Storage Environment
• Do not store, install, or operate the product in any of the following locations.
• Locations subject to direct sunlight.
• Locations subject to temperatures outside the range specified in the specifications.
• Locations subject to humidity outside the range specified in the specifications.
• Locations subject to condensation resulting from severe changes in temperature.
• Locations subject to corrosive or flammable gases.
• Locations subject to exposure to combustibles.
• Locations subject to dust (especially iron dust) or salts.
• Locations subject to exposure to water, oil, or chemicals.
• Locations subject to shock or vibration.
■
Transporting, Installation, and Wiring
• Always use the original shipping box when transporting the Inverter.
• Do not apply excessive shock to the Inverter or drop the Inverter. The Inverter may malfunction
or may be damaged.
• Do not connect an AC power supply voltage to the U, V, and W output terminals. Doing so will
damage the Inverter.
• Do not connect any load other than a three-phase inductive motor to the U, V, and W output
terminals.
• Do not connect an AC power supply voltage to the control I/O terminals. Doing so will damage
the Inverter.
• Use 600-V polyvinyl chloride (PVC) cable with a wire size of 0.75 to 2 mm
2
to wire the main
circuit terminals. Also, tighten the terminal screws on the terminal block to a torque of 0.8 to
1.0 N·m.
• Take appropriate and sufficient shielding countermeasures when installing systems in the fol-
lowing locations. Not doing so may result in malfunction or equipment damage.
• Locations subject to static electricity or other forms of noise.
• Locations subject to strong electromagnetic fields and magnetic fields.
• Locations close to power lines.
■
Operation and Maintenance
• This Inverter can be set to operate from low speed to high speed. Operate the Inverter only
after sufficiently confirming the allowable range for the motor installation being used.
• Take measures to assure safety before performing maintenance or inspection, or replacing
components.
Precautions for Safe Use
Summary of Contents for EasySpeed 3G3JE
Page 1: ...3G3JE Compact Simplified Inverters Cat No I547 E1 02 USER S MANUAL...
Page 3: ...USER S MANUAL 3G3JE Compact Simplified Inverters...
Page 18: ...Table of Contents XVI...
Page 19: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature...
Page 23: ...Chapter 2 Design 2 1 Installation 2 2 Wiring...
Page 86: ...Chapter 3 3 26 Operation...
Page 100: ...Chapter 4 4 14 Maintenance Operations...
Page 101: ...Chapter 5 Specifications 5 1 Inverter Specifications 5 2 Option Specifications...
Page 112: ...Chapter 5 5 12 Specifications...
Page 113: ...Chapter 6 Parameter Tables...
Page 118: ...Chapter 6 6 6 Parameter Tables...
Page 130: ...Chapter 7 7 12 Appendix...
Page 132: ...R 2 Revision History...