A Appendices
A - 38
E3NW-ECT EtherCAT Digital Sensor Communication Unit Operation Manual (E429)
•
This object sets the alarm output level of the Sensor with the unit number that is specified by the index.
•
This object executes the maximum sensitivity tuning for the Sensor with the unit number that is
specified by the index.
•
Set this object to 0001 hex to write data. It is always set to 0000 hex when reading data.
•
Allow at least 3 seconds for processing to be completed after executing full auto tuning setup.
•
This object executes the zero reset for the Sensor with the unit number that is specified by the index.
•
Set this object to 0001 hex to execute and 0000 hex to reset.
•
On the CA0, zero reset cannot be executed when the detection method is set to color mode.
* Items with asterisks are supported from E3NW-ECT version 1.03.
You can check the version with object index 100A hex. (Refer to "A-1-4 Communication Objects" on page A-4.)
•
This object turns OFF the emitted light for the Sensor with the unit number that is specified by the
index.
•
It is always set to 0000 hex when reading data.
4025 + (N-1)
×
80
hex
No_01 ... 30 Alarm Output Level Setting
Subindex 0: Number of Entries
Range: 01 hex
Unit: ---
Default: 01 hex
Attribute: ---
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Subindex 1: No_01 ... 30 Alarm Output Level Setting
Range: 0000 to 0064 hex
Unit: ---
Default: --- hex
Attribute: A
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
4030 + (N-1)
×
80
hex
No_01 ... 30 Maximum Sensitivity Tuning
Subindex 0: Number of Entries
Range: 02 hex
Unit: ---
Default: 02 hex
Attribute: ---
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Subindex 1: No_01 ... 30 Maximum Sensitivity Tuning IN1
Range: 0000 to 0001 hex
Unit: ---
Default: --- hex
Attribute: A
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
Subindex 1: No_01 ... 30 Maximum Sensitivity Tuning IN2
Range: 0000 to 0001 hex
Unit: ---
Default: --- hex
Attribute: A
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
4031 + (N-1)
×
80
hex
No_01 ... 30 Zero Reset
Subindex 0: Number of Entries
Range: 02 hex
Unit: ---
Default: 02 hex
Attribute: ---
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Subindex 1: No_01 ... 30 Zero Reset IN1
Range: 0000 to 0001 hex
Unit: ---
Default: --- hex
Attribute: A
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
Subindex 2*: No_01 ... 30 Zero Reset IN2
Range: 0000 to 0001 hex
Unit: ---
Default: --- hex
Attribute: A
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
4032 + (N-1)
×
80
hex
No_01 ... 30 Projection Lighting OFF
Subindex 0: Number of Entries
Range: 02 hex
Unit: ---
Default: 02 hex
Attribute: ---
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Subindex 1: No_01 ... 30 Projection Lighting OFF IN1
Range: 0000 to 0001 hex
Unit: ---
Default: --- hex
Attribute: A
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
Subindex 2*: No_01 ... 30 Projection Lighting OFF IN2
Range: 0000 to 0001 hex
Unit: ---
Default: --- hex
Attribute: A
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible