A - 37
A Appendices
E3NW-ECT EtherCAT Digital Sensor Communication Unit Operation Manual (E429)
A-
1 Object
Dictio
nary
A
A-1-7
Manufacturer
S
pecific
Obj
ec
ts
•
The setting range for the TA0 is 00000000 hex to 05F5E0FF hex.
*1 Items with asterisks are supported from E3NW-ECT version 1.03.
*2 Items with asterisks are supported from E3NW-ECT version 1.08.
You can check the version with object index 100A hex. (Refer to "A-1-4 Communication Objects" on page A-4.)
*1 Supported from E3NW-ECT Ver. 1.08
•
This object sets the keep setting of the Sensor with the unit number that is specified by the index.
•
During sensor OFF operation, commands other than an SDO command that cancels sensor OFF
cannot be received.
•
This object sets the keep setting of the Sensor with the unit number that is specified by the index.
•
This object is enabled only when output 1 mode.
4023 + (N-1)
×
80
hex
No_01 to 30 Keep Setting / Mutual interference prevention units setting*1/External input setting change *
1
/Sensor off
setting
*1
Subindex 0: Number of Entries
Range: 01 hex
Unit: ---
Default: 01 hex
Attribute: ---
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Subindex 1: No_01 ... 30 Keep Setting/ Mutual interference prevention units setting
*1
/External input setting change
*1
/Sensor off setting
*1
Range: 0000 to FFFF hex
Unit: ---
Default: --- hex
Attribute: A
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
Data
Setting
Keep Setting
Mutual Interference setting
External input setting
change
Sensor OFF
setting
SA0
EA
□
0
VD
□
0
FA
□
0/MA0
0000 hex
Keep OFF
Mutual Interference OFF
External input OFF
OFF
0001 hex
Keep ON
Mutual Interference 2 Units
Tuning
ON
0002 hex
Not used.
Mutual Interference 3 Units
Not used.
Not used.
0003 hex
Not used.
Mutual Interference 4 Units
Not used.
Not used.
0004 hex
Not used.
Mutual Interference 5 Units
Zero reset
Not used.
0005 hex
Not used.
Not used.
Not used.
Not used.
0006 hex
Not used.
Not used.
Synchronized detection END
output setting
Not used.
0007 hex
Not used.
Not used.
Not used.
Not used.
0008 hex
Not used.
Not used.
Not used.
Not used.
0009 hex
Not used.
Not used.
Synchronized detection
immediate output setting
Not used.
0010-FFFF hex
Not used.
Not used.
Not used.
Not used.
4024 + (N-1)
×
80
hex
No_01 ... 30 Hold Mode Setting / Zero reset automatic following
Subindex 0: Number of Entries
Range: 01 hex
Unit: ---
Default: 01 hex
Attribute: ---
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Subindex 1: No_01 ... 30 Hold Mode Setting
Range: 0000 to FFFF hex
Unit: ---
Default: --- hex
Attribute: A
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
Data
Setting
Hold Mode Setting
Zero reset automatic following
SA0
VD
□
0
0000 hex
Peak
Zero reset automatic following OFF
0001 hex
Bottom
Zero reset automatic following ON
0002 to FFFF hex
Not used.
Not used.
Summary of Contents for E3NC
Page 3: ...E3NW ECT EtherCAT Digital Sensor Communication Unit Operation Manual Revised March 2020...
Page 4: ......
Page 168: ...A Appendices A 64 E3NW ECT EtherCAT Digital Sensor Communication Unit Operation Manual E429...
Page 172: ...Revision 2 E3NW ECT EtherCAT Digital Sensor Communication Unit Operation Manual E429...
Page 173: ......