![background image](http://html1.mh-extra.com/html/omron/e3nc/e3nc_operation-manual_741093146.webp)
A Appendices
A - 42
E3NW-ECT EtherCAT Digital Sensor Communication Unit Operation Manual (E429)
•
This object sets the power tuning setting and tolerance setting high setting of the Sensor with the unit
number that is specified by the index.
•
The setting range for the tolerance setting high setting is
−
1,999,999 to 9,999,999 (FFE17B81 hex to
0098967F hex).
*1 Items with asterisks are supported from E3NW-ECT version 1.03.
*2 Items with asterisks are supported from E3NW-ECT version 1.08.
You can check the version with object index 100A hex. (Refer to "A-1-4 Communication Objects" on page A-4.)
Power Tuning Setting data
•
This object sets the power tuning level and tolerance setting low setting of the Sensor with the unit
number that is specified by the index.
•
The setting range is for the power tuning level is 100 to 9999 (00000064 hex to 0000270F hex).
•
The setting range for the tolerance setting low setting is
−
1,999,999 to 9,999,999 (FFE17B81 hex to
0098967F hex).
*1 Items with asterisks are supported from E3NW-ECT version 1.03.
*2 Items with asterisks are supported from E3NW-ECT version 1.08.
You can check the version with object index 100A hex. (Refer to "A-1-4 Communication Objects" on page A-4.)
403B + (N-1)
×
80
hex
No_01 ... 30 Power Tuning Setting, Tolerance Setting High*, and Scaling Setting Low *2
Subindex 0: Number of Entries
Range: 02 hex
Unit: ---
Default: 02 hex
Attribute: ---
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Subindex 1: No_01 ... 30 Power Tuning Setting IN1, Tolerance Setting High*, and Scaling Setting Low *2
Range*:
−
1,999,999 to 9,999,999
(FFE17B81 hex to 0098967F hex)
Unit: ---
Defaults: --- hex
Attribute: A
Size: 4 bytes (INT32)
Access: RW
PDO map: Not possible
Subindex 2*: No_01 ... 30 Power Tuning Setting IN2
Range*:
−
1,999,999 to 9,999,999
(FFE17B81 hex to 0098967F
hex)
Unit: ---
Default: --- hex
Attribute: A
Size: 4 bytes (INT32)
Access: RW
PDO map: Not possible
Data
Setting
00000000 hex
Power Tuning Setting ON
00000001 hex
Power Tuning Setting OFF
00000002 to FFFFFFFF hex
Not used.
403C + (N-1)
×
80
hex
No_01 ... 0 Power Tuning Level and Tolerance Setting Low*, and Scaling Setting High *2
Subindex 0: Number of Entries
Range: 02 hex
Unit: ---
Default: 02 hex
Attribute: ---
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Subindex 1: No_01 ... 30 Power Tuning Setting IN1 and Tolerance Setting High*, and Scaling Setting High *2
Range*:
−
1,999,999 to 9,999,999
(FFE17B81 hex to 0098967F hex)
Unit: ---
Defaults: --- hex
Attribute: A
Size: 4 bytes (INT32)
Access: RW
PDO map: Not possible
Subindex 2*: No_01 ... 30 Power Tuning Level IN2
Range*:
−
1,999,999 to 9,999,999
(FFE17B81 hex to 0098967F
hex)
Unit: ---
Default: --- hex
Attribute: A
Size: 4 bytes (INT32)
Access: RW
PDO map: Not possible
Summary of Contents for E3NC
Page 3: ...E3NW ECT EtherCAT Digital Sensor Communication Unit Operation Manual Revised March 2020...
Page 4: ......
Page 168: ...A Appendices A 64 E3NW ECT EtherCAT Digital Sensor Communication Unit Operation Manual E429...
Page 172: ...Revision 2 E3NW ECT EtherCAT Digital Sensor Communication Unit Operation Manual E429...
Page 173: ......