![background image](http://html1.mh-extra.com/html/omron/e3nc/e3nc_operation-manual_741093098.webp)
8 Troubleshooting and Maintenance
8 - 14
E3NW-ECT EtherCAT Digital Sensor Communication Unit Operation Manual (E429)
Event name
Non-volatile Memory Hardware Error
Event code
04A10000 hex
Meaning
An error occurred in non-volatile memory.
Source
EtherCAT Master Function Module
Source details
Slave
Detection
timing
When establish-
ing communica-
tions after turning
ON power to the
slave
Error attributes
Level
Observation
Recovery
---
Log category
System
Effects
User program
Continues.
Operation
Non-volatile memory cannot be written.
Indicators
EtherCAT NET RUN
EtherCAT NET ERR
EtherCAT LINK/ACT
---
---
---
System-defined
variables
Variable
Data type
Name
None
---
---
Cause and
correction
Assumed cause
Correction
Prevention
Non-volatile memory failure
Replace the EtherCAT Communica-
tions Unit or the EtherCAT slave.
None
Attached
information
None
Precautions/
Remarks
This error is not recorded in the error log of the slave.