A - 33
A Appendices
E3NW-ECT EtherCAT Digital Sensor Communication Unit Operation Manual (E429)
A-
1 Object
Dictio
nary
A
A-1-7
Manufacturer
S
pecific
Obj
ec
ts
•
This object sets the timer value 2 of the Sensor with the unit number that is specified by the index.
•
Timer value 2 is used for the OFF delay.
•
The setting units for the FA
□
0, LA0, SA0, TA0, MA0, FAH0, EA0, AA
□
0, VA
□
0, VD
□
0 are 1 ms, and
the setting range is 0x0001 (1) - 0x270F (9999).
For the CA0, the settings are selected in increments of 1 (units of 0.1 ms) from 0.1 ms to 0.5 ms, in
increments of 5 (units of 0.5 ms) from 0.5 ms to 5 ms, and in increments of 10 (units of 1ms) from 5
ms to 9999 ms.
The setting range is 0x00000001Hex (1) - 0x00018696 (99990).
•
This object sets the DPC setting and number of display digits of the Sensor with the unit number that
is specified by the index.
* Items with asterisks are supported from E3NW-ECT version 1.03.
You can check the version with object index 100A hex. (Refer to "A-1-4 Communication Objects" on page A-4.)
DPC Setting
Display Digits Setting
4010 + (N-1)
×
80
hex
No_01 ... 30 Timer Value 2
Subindex 0: Number of Entries
Range: 02 hex
Unit: ---
Default: 02 hex
Attribute: ---
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Subindex 1: No_01 ... 30 Timer Value 2 IN1
Range: 00000001 hex to 00018696 hex
Unit: ---
Default: --- hex
Attribute: A
Size: 4 bytes (U32)
Access: RW
PDO map: Not possible
Subindex 2: No_01 ... 30 Timer Value 2 IN2
Range: 00000001 hex to 00018696 hex
Unit: ---
Default: --- hex
Attribute: A
Size: 4 bytes (U32)
Access: RW
PDO map: Not possible
4011 + (N-1) × 80
hex
No_01 ... 30 DPC Setting and Display Digits*
Subindex 0: Number of Entries
Range: 02 hex
Unit: ---
Default: 02 hex
Attribute: ---
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Subindex 1: No_01 ... 30 DPC Setting IN1 and Display Digits*
Range: 0000 hex to FFFF hex
Unit: ---
Default: --- hex
Attribute: A
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
Subindex 2*: No_01 ... 30 DPC Setting IN2
Range: 0000 hex to FFFF hex
Unit: ---
Default: --- hex
Attribute: A
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
Data
Setting
0000 hex
DPC OFF
0001 hex
DPC ON
0002 to FFFF hex
Not used.
Data
Setting
0000 hex
4 digits
0001 hex
3 digits
0002 hex
2 digits
0003 hex
1 digit
0004 hex
0 digit
0005 to FFFF hex
Not used.