![background image](http://html1.mh-extra.com/html/omron/e3nc/e3nc_operation-manual_741093151.webp)
A - 47
A Appendices
E3NW-ECT EtherCAT Digital Sensor Communication Unit Operation Manual (E429)
A-
1 Object
Dictio
nary
A
A-1-7
Manufacturer
S
pecific
Obj
ec
ts
To set tuning information to a different amplifier (CA0 only)
•
If you want to copy tuning information to another amplifier, read the index below in the original
amplifier and write the information that is read to the other amplifier.
Write all index number items in the table below that apply to the detection method in order.
* Tuning information cannot be set for output 2. For details, see the detection method selection item (Index 4038 +
(N - 1) × 80 Hex).
•
If you want to set tuning information to a different amplifier, use this index.
•
If you want to set tuning information to a different amplifier, use this index.
* is supported from E3NW-ECT Ver 1.08
•
The External input detection time range for the VD
□
0 is 5 to 9999 ms.
•
If you want to set tuning information to a different amplifier, use this index.
•
If you want to set tuning information to a different amplifier, use this index.
Index No
Name
Detection method
Contrast
Color
4038+(N-1)×80 hex
Detection method selection
1st
1st
400B+(N-1)×80 hex
Detection function
2nd
2nd
4064+(N-1)×80 hex
Tuning setting (1)
3rd
3rd
4065+(N-1)×80 hex
Tuning setting (2)
4th
4th
4066+(N-1)×80 hex
Tuning setting (3)
Not applicable
5th
4067+(N-1)×80 hex
Tuning setting (4)
Not applicable
6th
4068+(N-1)×80 hex
Tuning setting (5)
Not applicable
7th
4004+(N-1)×80 hex
Threshold 1 setting
5th
8th
4005+(N-1)×80 hex
Threshold 2 setting
6th
9th
4064 + (N-1) × 80
hex
No_01 ... 30 Tuning Setting (1)
Subindex 0: Number of Entries
Range: 01 hex
Unit: ---
Default: 01 hex
Attribute: ---
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Subindex 1: No_01 ... 30 Tuning Setting (1)
Range: 0000 to FFFF hex
Unit: ---
Default: --- hex
Attribute: A
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
4065 + (N-1) × 80
hex
No_01 ... 30 Tuning Setting (2)
Subindex 0: Number of Entries
Range: 01 hex
Unit: ---
Default: 01 hex
Attribute: ---
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Subindex 1: No_01 ... 30 Tuning Setting (2)
Range: 0000 to FFFF hex
Unit: ---
Default: --- hex
Attribute: A
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
4066 + (N-1) × 80
hex
No_01 ... 30 Tuning Setting (3) External input detection time*
Subindex 0: Number of Entries
Range: 01 hex
Unit: ---
Default: 01 hex
Attribute: ---
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Subindex 1: No_01 ... 30 Tuning Setting (3)
Range: 0000 to FFFF hex
Unit: ---
Default: --- hex
Attribute: A
Size: 4 bytes (U32)
Access: RW
PDO map: Not possible
4067 + (N-1) × 80
hex
No_01 ... 30 Tuning Setting (4)
Subindex 0: Number of Entries
Range: 01 hex
Unit: ---
Default: 01 hex
Attribute: ---
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Subindex 1: No_01 ... 30 Tuning Setting (4)
Range: 0000 to FFFF hex
Unit: ---
Default: --- hex
Attribute: A
Size: 4 bytes (U32)
Access: RW
PDO map: Not possible
Summary of Contents for E3NC