A - 29
A Appendices
E3NW-ECT EtherCAT Digital Sensor Communication Unit Operation Manual (E429)
A-
1 Object
Dictio
nary
A
A-1-7
Manufacturer
S
pecific
Obj
ec
ts
•
This object reads the status of the Sensor with the unit number that is specified by the index.
•
This object reads the zero reset level for the Sensor Amplifier with the unit number that is specified by
the index.
* Items with asterisks are supported from E3NW-ECT version 1.03.
You can check the version with object index 100A hex. (Refer to "A-1-4 Communication Objects" on page A-4.)
4006 + (N-1)
×
80
hex
No_01 ... 30 Sensor Status
Subindex 0: Number of Entries
Range: 01 hex
Unit: ---
Default: 01 hex
Attribute: ---
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Subindex 1: No_01 ... 30 Sensor Status
Range: 0000 to FFFF hex
Unit: ---
Default: --- hex
Attribute: ---
Size: 2 bytes (U16)
Access: RO
PDO map: Not possible
Data
Sensor Status
Bit 00
Normal operation (This bit is normally set to 1, and changes to 0 if the bits 08 on change to 1.)
Bit 01
CH1 DPC status (This bit is set to "1" when the DPC is ON, and "0" when the DPC is OFF.)
Bit 02
CH1 Smart Tuning Status (This bit is set to "1" when ST is ON, and "0" when ST is OFF.)
Bit 03
CH2 DPC status (This bit is set to "1" when the DPC is ON, and "0" when the DPC is OFF.)
* MA0 only
Bit 04
CH2 Smart Tuning Status (This bit is set to "1" when ST is ON.)
* MA0 only
Bit 05 to 07
Not used.
Bit 08
DPC error (FA
□
0, LA0, MA0, or FAH0)
Bit 09
EEPROM error (all models)
Bit 10
Load short-circuit error (all models)
Bit 11
Head-related error (SA0/TA0)
Bits 12 to 15
Not used.
4007 + (N-1)
×
80
hex
No_01 ... 30 Zero Reset Level
Subindex 0: Number of Entries
Range: 02 hex
Unit: ---
Default: 02 hex
Attribute: ---
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Subindex 1: No_01 ... 30 Zero Reset Level IN1
Range:
−
99,999,999 to 99,999,999
(FA0F1F01 to 05F5E0FF hex)
Unit: ---
Default: --- hex
Attribute: ---
Size: 4 bytes (INT32)
Access: RO
PDO map: Not possible
Subindex 2*: No_01 ... 30 Zero Reset Level IN2
Range:
−
99,999,999 to 99,999,999
(FA0F1F01 to 05F5E0FF hex)
Unit: ---
Default: --- hex
Attribute: ---
Size: 4 bytes (INT32)
Access: RO
PDO map: Not possible