50
Initial Setting for Connecting Online
Section 7-1
7-1
Initial Setting for Connecting Online
Initial Settings for CPU Unit and Position Control Unit
1,2,3...
1.
Set the unit number for the Position Control Unit (using the rotary switch on
the front panel)
2.
Set the DIP switch on the CPU Unit or the Controller Section of the NSJ
Controller.
a.
For Communications via Toolbus:
• When using the peripheral port, set SW4 to OFF, or set SW4 to ON
and make appropriate setting of PLC Setup (set the PLC Setup Ad-
dress 160 on the Programming Console to 0400 Hex).
• When using the RS-232C port, set SW5 to ON, or set SW5 to OFF and
make appropriate setting of PLC Setup (set the PLC Setup Address
160 on the Programming Console to 0400 Hex).
b.
For Communications via SYSMAC WAY (Host Link):
• When using the peripheral port, set SW4 to ON, or set SW4 to OFF
and make appropriate setting of PLC Setup. (Set the PLC Setup Ad-
dress 144 on the Programming Console to its default, 0000 Hex. If the
default setting has not been changed, leave the setting as it is.)
• When using the RS-232C port, set SW5 to OFF, or set SW5 to ON and
make appropriate setting of PLC Setup. (Set the PLC Setup Address
160 on the Programming Console to its default, 0000 Hex. If the default
setting has not been changed, leave the setting as it is.)
3.
Create the I/O tables (using the CX-Programmer or a Programming Con-
sole).
7-2
Setting/Changing Communications Specific
Communications Setting
1,2,3...
1.
In the CX-Motion-NCF Basic Window, select
PLC - Communications Set-
ting
, click
in the toolbar, or right-click and select
Communications
Setting
from the pop-up menu. The following dialog box will be displayed.
2.
Select the Network Type.
Click the drop-down list of the Network Type and select an appropriate net-
work type.
3.
Select the Baud Rate.
Click the drop-down list of the Baud Rate and select an appropriate baud
rate.
4.
Detailed Settings
For more detailed settings, click the
Settings
Button.
Summary of Contents for CX-MOTION-NCF - V1.8
Page 2: ...CXONE AL C V3 CXONE AL D V3 CX Motion NCF Ver 1 8 Operation Manual Revised October 2008...
Page 3: ...iv...
Page 5: ...vi...
Page 21: ...xxii Application Precautions 5...
Page 33: ...12 Connecting to PLC Section 2 2...
Page 36: ...15 Screen Name Section 3 1 Edit Parameter Windows...
Page 37: ...16 Screen Name Section 3 1 Monitor Windows Axis Monitor Window Unit Monitor Window...
Page 63: ...42 Editing Servo Parameters Section 5 2...
Page 68: ...47 Print Section 6 5 Print Samples An example of printed Unit Parameters is shown below...
Page 89: ...68 Writing to Flash Memory Section 7 6...
Page 103: ...82 Axis Monitor Section 8 2...
Page 109: ...88 Test Run Section 9 1...
Page 133: ...112 Index...
Page 137: ...116 Revision History...