85
Test Run
Section 9-1
JOG Operation
Execution
1,2,3...
1.
Select the axis to jog in the Test Run Window.
2.
If a connection has not been established at this point, press the
Establish
Button to establish the connection.
3.
Press the
Servo Lock
Button.
4.
Enter the desired speed in the
JOG Settings
. To use the override, select
the
Enable
Check Box and enter the desired override value. Click the
Write
Button to write the set values to the Position Control Unit.
5.
Press
(or
). Jogging will continue while the button is pressed
down. Release the button to stop the JOG operation.
Note
(1) Pressing a
JOG
Button (
or
) will actually operate the motor at
the designated speed. Execute jogging only after confirming safety.