9
Connecting to a PLC
Section 2-2
to the PLC. The characteristics of the network protocols are as shown be-
low.
Connection Methods
Use one of the following methods to connect the personal computer (CX-
Motion-MCH) and PLC (CPU Unit). It is also possible to connect the personal
computer to the port on the CS/CJ Series Serial Communications Unit. In that
case, the only network type that can be used is Host Link.
Connection Cables
Note
When connecting the connectors of the above cables to the PLC's RS-232C
port, discharge any static build-up (e.g., by touching a grounded metal object)
before touching the connectors. Although XW2Z-
@@@
S-CV Cables use the
anti-static XM2S-0911-E Connector Hood (thus reducing the possibility of
static build-up), be sure to discharge any static as a safety precaution.
Network type
Characteristics
Toolbus
Faster communications. If possible, use this network type.
• For CS/CJ Series, the baud rate on the peripherals can be
detected automatically, and be connected.
• Only 1 on 1 connection possible.
• For CX-Motion-MCH, it can also be connected to a modem.
SYSMAC WAY
(Host Link)
Used for communications with general host computers.
• Slower than Toolbus.
• Not only 1 on 1 connection, but also 1-many connection
possible.
• Connecting to a modem and optical adaptor possible.
Connecting to Peripheral Port
Connecting to RS-232C Port
IBM PC/AT or compatible
IBM PC/AT or compatible
9-pin connector
9-pin connector
9-pin connector
CS1W-CN118 (0.1 m)
CS1W-CN226 (2.0 m)
CS1W-CN626 (6.0 m)
XW2Z-200S-CV (2.0 m)
XW2Z-500S-CV (5.0 m)
Peripheral port
on CPU Unit
Built-in RS-232C port
on CPU Unit or Serial
Communications Unit
Unit
Port on Unit
Computer
Port on
computer
Network type
(serial commu-
nications
mode)
Model number
Length
Remarks
CPU Unit
Built-in
peripheral
port
IBM PC/AT
compatible
D-SUB, 9-
pin, male
SYSMAC WAY
(Host Link)
CS1W-CN226
2 m
---
CS1W-CN626
6 m
Built-in RS-
232C port
(D-SUB, 9-
pin, female)
IBM PC/AT
compatible
D-SUB, 9-
pin, male
SYSMAC WAY
(Host Link)
XW2Z-200S-CV 2 m
Uses anti-static
connector
XW2Z-500S-CV 5 m
Serial
Communi-
cations
Unit
RS-232C port
(D-SUB, 9-
pin, female)
IBM PC/AT
compatible
D-SUB, 9-
pin, male
SYSMAC WAY
(Host Link)
XW2Z-200S-CV 2 m
Uses anti-static
connector
XW2Z-500S-CV 5 m
Summary of Contents for CX-MOTION - 06-2008
Page 1: ...CX Motion MCH Cat No W448 E1 04 OPERATION MANUAL...
Page 2: ...CXONE AL C V3 CXONE AL D V3 CX Motion MCH Operation Manual Revised June 2008...
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x TABLE OF CONTENTS...
Page 15: ...xvi Note All new functions can be used in Motion Control Units with unit version 3 0 or later...
Page 31: ...12 Connecting to a PLC Section 2 2...
Page 47: ...28 Operations Listed by Purpose Section 3 2...
Page 71: ...52 Exporting File Section 6 4...
Page 91: ...72 Debugging the Program Section 9 3...
Page 95: ...76 Data Traces Section 10 1...
Page 99: ...80 Verifying Backup File with MC Unit Section 11 3...
Page 109: ...90 Printing Section 13 1...
Page 133: ...114 Error Codes Section 15 2...