System Configurations
Section 1-2
Expansion Units
CPM2C-MAD11
Analog I/O Unit
CPM2C-TS001/101
Temperature Sensor Unit
CPM2C-SRT21
CompoBus/S I/O Link Unit
Unit
Max. number
of Units
Inputs
Outputs
Model
Analog I/O Unit
2 analog inputs
1 analog output
4
2 points, 2 words
allocated
1 point, 1 word allo-
cated
CPM2C-MAD11
Temperature Sen-
sor Unit
2 thermocouple
inputs
4
2 points, 2 words
allocated
---
CPM2C-TS001
2 platinum resis-
tance thermometer
inputs
2 points, 2 words
allocated
---
CPM2C-TS101
CompoBus/S I/O
Link Unit
8 input points and 8
output points for
the built-in outputs
and inputs of the
Master Unit
5
8 points, 1 word
allocated
(Inputs from the
Master)
8 points, 1 word
allocated
(Outputs to the
Master)
CPM2C-SRT21