CPM2C-S Features and Functions
Section 1-1
One-to-one PC Link
A CPM2C-S can be linked directly to another CPM2C-S, CQM1, CPM1,
CPM1A, CPM2A, CPM2C, SRM1(-V2), C200HS, or C200HX/HG/HE PC. The
1:1 PC Link allows automatic data link connections. The PC must be con-
nected to the communications port as an RS-232C port (not as a peripheral
port).
1-1-2
Overview of CPM2C-S Functions
Main function
Variations/Details
CompoBus/S Master
functions
•
Remote I/O devices can be allocated up to 256 I/O points (128 inputs and 128 outputs) in
input area IR 020 to IR 027 and output area IR 030 to IR 037.
•
The node numbers can be set to 0 to 7 (128-point mode) or 0 to 15 (256-point mode).
•
The communications mode can be set to high-speed mode (max. length 100 m) or long-dis-
tance mode (max. length 500 m).
DeviceNet Slave
functions
•
Up to 64 words (32 input words and 32 output words) can be allocated to the DeviceNet
Master’s I/O. The Master’s I/O can be allocated to the following data areas.
IR 000 to IR 049
IR 200 to IR 227
DM 0000 to DM 2047
LR 00 to LR 15
HR 00 to HR 19
AR 00 to AR 23 (CPM2C
→
Master; read-only)
TC 000 to TC 255
•
Explicit message communications are supported. Any CPM2C-S data area can be
accessed from the DeviceNet Master.
•
The communications speed can be set to 500 kbps (total network length 100 m max.),
250 kbps (total network length 250 m max.), or 125 kbps (total network length 500 m max.).
Interrupts
Interrupt inputs
2 inputs
Response time: 50
µ
s
Interval timer interrupts
1 input
Set value: 0.5 to 319,968 ms
Precision: 0.1 ms
Scheduled interrupts
One-shot interrupt
High-speed counters
High-speed counter
1 input, see note 1.
Differential phase mode (5 kHz)
Pulse plus direction input mode (20 kHz)
Up/down input mode (20 kHz)
Increment mode (20 kHz)
No interrupt
Count-check interrupt
(An interrupt can be generated when the
count equals the set value or the count lies
within a preset range.)
Interrupt inputs (counter mode)
2 inputs
Incrementing counter (2 kHz)
Decrementing counter (2 kHz)
No interrupt
Count-up interrupt
Summary of Contents for CPM2C-S100C
Page 2: ......
Page 3: ...CPM2C S Programmable Controller Operation Manual Revised September 2009 ...
Page 4: ...iv ...
Page 6: ...vi ...
Page 10: ......
Page 14: ...xiv ...
Page 180: ...158 One to one PC Link I O Response Time Section 7 4 ...
Page 222: ...200 Programming Example Section 8 3 ...
Page 250: ......
Page 256: ......
Page 258: ......
Page 260: ...238 Support Software Appendix C ...
Page 268: ......