V600/V620 ID Controller Protocol
Appendix M
DIP Switch Settings
V600/620-CD1D DIP Switches
DIP Switch 1
Baud rate
(bps)
2,400
4,800
9,600
19,200
Display mode
Error display mode
I/O display mode
Local communications mode setting
Speed priority setting
Distance priority setting
1
2
3
4
5
6
7
8
7
7
7
7
8
8
8
8
2
2
1
1
2
1
1
1
Data
length (bit)
STOP
bits (bit)
Parity type
E
O
O
E
N
O
N
E
•
SW7 Setting
This setting is only valid if the EEPROM-type (batteryless-
type) Data Carrier (DC) is accessed. The setting of SW7 does
not work with the SRAM-type (battery-type) DC. SW7 must
be set to OFF when the V620 is used.
Not used (Always keep it OFF.)