294
E5ZE Temperature Controller Write Protocol
Appendix F
Write HB and HS Alarm Valid Channels (Sequence No. 170 (Hex
00AA))
Writes the valid or invalid channels of HB alarm and HS alarm.
Send Data Word Allocation (3rd Operand of PMCR(260))
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Write Heater Burnout and SSR Failure Detection Current
(Sequence No. 171 (Hex 00AB))
Writes the currents for detecting heater burnouts and SSR failures.
Send Data Word Allocation (3rd Operand of PMCR(260))
Offset
Contents (data format)
Data
+0
Number of send data words
(4 digits Hex)
0003 (fixed)
+1
Unit No. (2 digits Hex)
00 to 0F
+2
Write code (2 digits Hex)
00 to FF
First word of
send data
Number of send data words
+0
+1
+2
(Undefined)
Unit No.
(Undefined)
Write code
First word of
send data
Number of send data words
+0
+1
+2
+3
+4
+5
+16
+17
(Undefined)
Unit No.
Heater burnout detection current
~
~
SSR failure detection current
Heater burnout detection current
SSR failure detection current
Channel 0
Channel 7
Heater burnout detection current
SSR failure detection current
Channel 1