43
Message Service Procedure
Section 2-2
6.
Set the data link mode.
Note
When using fewer than 33 nodes, make sure that the Wired Network
62 Node Enable Bit in the DM Parameter Area software switches is
turned OFF to restrict the network to 32 nodes maximum. To con-
struct a network containing more than 32 nodes, all nodes must use
the CS1W-CLK21-V1, CS1W-CLK23, CJ1W-CLK21-V1, or CJ1W-
CLK23.
7.
Create the user program.
Contents
Method
Nodes
Page
Enable 62 nodes for a
wired network.
Use Support Soft-
ware for the PLC or a
Programming Con-
sole.
All nodes
This setting must be
made when construct-
ing a network that
uses a node address
higher than 32 (See
note.)
Contents
Remarks
Page
a. Prepare the send and receive
data in memory.
Stored in the memory areas of the
source node
b. Prepare the control data for the
communications instruction.
c. Check the conditions for exe-
cuting the SEND/RECV or
CMND instruction.
The standard input conditions are
the Active Node Flags for the
source and destination nodes, and
the Port Enabled Flag.
d. Execute the SEND/RECV or
CMND instruction.
---
e. Execute other instructions are
required for the results of the
communications instruction,
(e.g., retry or error processing
if an error occurs).
The standard input condition is the
Port Error Flags.
C200HX/HG/HE PLCs have 1
communications port for each
operating level. When 2 or more
communications instructions are
executed at the same time, exclu-
sive control is necessary.
CS-series, CJ-series, CVM1, and
CV-series PLCs have 8 communi-
cations ports. When 9 or more
communications instructions are
executed at the same time, exclu-
sive control is necessary.
CQM1H-series PLCs have only 1
communications port. When 2 or
more communications instructions
are executed at the same time,
exclusive control is necessary.
Summary of Contents for C200HW-CLK21
Page 3: ...iv ...
Page 9: ...x ...
Page 12: ...xiii TABLE OF CONTENTS Index 367 Revision History 373 ...
Page 13: ...xiv ...
Page 19: ...xx ...
Page 57: ...32 Application Precautions Section 1 5 Example CX Programmer Response Timeout Setting ...
Page 69: ...44 Message Service Procedure Section 2 2 ...
Page 111: ...86 Constructing Networks with Repeater Units Section 3 4 ...
Page 154: ...129 Setting Data Links Section 5 2 Device Information Setting Data Link Tables ...
Page 261: ...236 Response Codes Section 6 7 ...
Page 297: ...272 Message Delay Times Section 8 4 ...
Page 353: ...328 Handling Precautions Section 9 6 ...
Page 364: ...339 Changing the Data Link Tables with Active Data Links Section 10 2 ...
Page 365: ...340 Changing the Data Link Tables with Active Data Links Section 10 2 ...
Page 369: ...344 Standard Models Appendix A ...
Page 391: ...366 Using the Relay Terminal Block Appendix C ...
Page 397: ...372 Index ...
Page 401: ...376 Revision History ...