241
Remote Programming and Monitoring
Section 7-2
CX-Programmer
A CX-Programmer connected to a CS/CJ-series, C200HX/HG/HE, CVM1,
CV-series, or CQM1H CPU Unit can program and monitor a CPU Unit on the
same network. Programming and monitoring are possible, including CPU
Units that are different to the one to which the Programming Device is con-
nected.
7-2-2
Remote Controller Link Networks
SYSMAC Support Software or CV Support Software
A Programming Device connected to a CVM1 or CV-series CPU Unit can pro-
gram and monitor a CVM1 or CV-series PLC on another Controller Link Net-
work through a CVM1 or CV-series PLC. Other types of PLC cannot be
programmed or monitored on remote networks.
CX-Programmer
Programming Device
Programming
and monitoring
Note
Remote programming and monitoring are possible from a factory automation
node computer using the CX-Programmer.
Controller Link Network
CS/CJ-series,
C200HX/HG/HE,
CVM1, CV-series,
or CQM1H PLC
CS/CJ-series,
C200HX/HG/HE,
CVM1, CV-series,
or CQM1H PLC
Controller Link Network
Programming
and monitoring
CS/CJ-series PLC
Controller Link Network
Controller Link Network
SYSMAC Support
Software (CVM1 Only)
or
CV Support Software
Programming Device
Note
Remote programming and monitoring is not possible from computer nodes. Computer
nodes can only monitor Controller Link Network status. A Programming Device connected
to a C200HX/HG/HE PLC cannot remotely program or monitor a node on a remote network.
Controller Link Network
Controller Link Network
Programming
and monitoring
CVM1 or
CV-series PLC
Controller Link
Support Software
CS/CJ-series, CVM1,
or CV-series PLC
CVM1 or
CV-series PLC
CS/CJ-series, CVM1,
or CV-series PLC
Summary of Contents for C200HW-CLK21
Page 3: ...iv ...
Page 9: ...x ...
Page 12: ...xiii TABLE OF CONTENTS Index 367 Revision History 373 ...
Page 13: ...xiv ...
Page 19: ...xx ...
Page 57: ...32 Application Precautions Section 1 5 Example CX Programmer Response Timeout Setting ...
Page 69: ...44 Message Service Procedure Section 2 2 ...
Page 111: ...86 Constructing Networks with Repeater Units Section 3 4 ...
Page 154: ...129 Setting Data Links Section 5 2 Device Information Setting Data Link Tables ...
Page 261: ...236 Response Codes Section 6 7 ...
Page 297: ...272 Message Delay Times Section 8 4 ...
Page 353: ...328 Handling Precautions Section 9 6 ...
Page 364: ...339 Changing the Data Link Tables with Active Data Links Section 10 2 ...
Page 365: ...340 Changing the Data Link Tables with Active Data Links Section 10 2 ...
Page 369: ...344 Standard Models Appendix A ...
Page 391: ...366 Using the Relay Terminal Block Appendix C ...
Page 397: ...372 Index ...
Page 401: ...376 Revision History ...