Standard Models
Appendix A
Communications Cables (Twisted-pair Cables)
Relay Terminal Block
Personal Computer Network Configuration Tools
Note
Windows 95 cannot be used when communicating through a Controller Link Support Board (PCI bus) or
SYSMAC Link Support Board (PCI bus).
CPU Units and Programming Devices
CPU Units
Model
Manufacturer
Remarks
Li2Y-FCY2 x 0.56 qmm
Kromberg & Schubert,
Komtec Department
German company
1 x 2 x AWG
–
20PE +
Tr.CUSN + PVC
Draka Cables Industrial
Spanish company
#9207
Belden
USA company
ESVC 0.5 x 2 C-1362
Bando Densen Co.
Japanese company
ESNC 0.5 x 2 C-99-087B
Nihon Electric Wire &
Cable Co.
Japanese company
ESPC 1P x 0.5 mm
2
Nagaoka Electric Wire
Co., Ltd.
Japanese company
Name
Model number
Remarks
Wired Controller Link Unit
Relay Terminal Block
CJ1W-TB101
Cannot be used on the
nodes on both ends of the
network.
Applicable
computer
Name
Model number
Applicable PLCs
IBM PC/AT or
compatible run-
ning Windows
98SE, Me, 2000,
XP, or NT 4.0
CX-Integrator
CXONE-AL
@@
C-EV2
CXONE-AL
@@
D-EV2
CS/CJ-series
IBM PC/AT or
compatible run-
ning Windows 95
(See note.), 98,
NT 4.0, 2000, or
XP
CX-Program-
mer with CX-Net
WS02-CXPC
@
-EV
@
(version 2.1 or higher)
CS/CJ-series,
C200HX/HG/HE,
CVM1, CV-series,
and CQM1H-series
PLCs
PLC
Model number
Remarks
CS-series PLCs
CS1H-CPU67-V1
CS1H-CPU66-V1
CS1H-CPU65-V1
CS1H-CPU64-V1
CS1H-CPU63-V1
CS1G-CPU45-V1
CS1G-CPU44-V1
CS1G-CPU43-V1
CS1G-CPU42-V1
Earlier versions of the
CPU Units can also be
used.
CJ-series PLCs
CS1G-CPU45
CS1G-CPU44
---
Summary of Contents for C200HW-CLK21
Page 3: ...iv ...
Page 9: ...x ...
Page 12: ...xiii TABLE OF CONTENTS Index 367 Revision History 373 ...
Page 13: ...xiv ...
Page 19: ...xx ...
Page 57: ...32 Application Precautions Section 1 5 Example CX Programmer Response Timeout Setting ...
Page 69: ...44 Message Service Procedure Section 2 2 ...
Page 111: ...86 Constructing Networks with Repeater Units Section 3 4 ...
Page 154: ...129 Setting Data Links Section 5 2 Device Information Setting Data Link Tables ...
Page 261: ...236 Response Codes Section 6 7 ...
Page 297: ...272 Message Delay Times Section 8 4 ...
Page 353: ...328 Handling Precautions Section 9 6 ...
Page 364: ...339 Changing the Data Link Tables with Active Data Links Section 10 2 ...
Page 365: ...340 Changing the Data Link Tables with Active Data Links Section 10 2 ...
Page 369: ...344 Standard Models Appendix A ...
Page 391: ...366 Using the Relay Terminal Block Appendix C ...
Page 397: ...372 Index ...
Page 401: ...376 Revision History ...