Ink Tempera‐
ture Control
This icon controls the ink heater and also displays the ink
temperature. The state of the button reflects the status of
the ink heater. The heater times out after two hours of in-
activity (time can be changed up to four hours by a serv-
ice technician). If the ink heater is turned off when the
timeout period has expired, the button changes its status
to unchecked.
The print heads must be at operating temperature (47°C /
116°F) before a job will start printing.
NOTE
If this button is flashing, it indicates an error.
Click on the Ink Status button to check the ink
system.
UV Curing
Lamp Control
This icon controls the UV curing lamps. The state of the
button reflects the state of the lamps. The UV lamps will
timeout after 15 minutes of inactivity (time can be
changed by a service technician). If lamps are extinguish-
ed when the timeout expired, then the button changes its
status to unchecked. If lamps are off before the print
starts, then lamps are turned on automatically and the
button would reflect the state accordingly.
Table vac‐
uum
This button controls the table vacuum and duplicates the
function of the table vacuum foot switch. The button re-
flects the actual state of the table vacuum. There is an au-
tomatic timeout that will turn the table vacuum off. The
actual time is set in the Settings module under Printer.
NOTE
Once turned off, vacuum cannot be turned on
again for approximately 5 seconds.
Start
This icon can be used to start a flatbed print job (same
function as the physical button on the table).
4
Print Job Control Module
52
Chapter 4 - How to Navigate the User Interface
User Manual: Arizona (AZ) 440 GT, AZ 440 XT, AZ 460 GT, AZ 460 XT, AZ 480 GT, AZ 480 XT - Rev. B, 4/2013