Copyright 2010-2015 Obihai Technology, Inc.
182
upload a prompt file and process the file accordingly.
Warning: All the existing prompts in the device will be removed
first when applying the backup file; this process cannot be undone
.
Backup Configuration
The current configuration of the OBi device can be backed up and stored as a file in XML format at a user specified
location. The default name of the file is “backup
xxxxxxxxxxxx
.xml”, where the
xxxxxxxxxxxxx
x represents the MAC
address of unit.
When backing up a device’s configuration, you may select the following three options before selection of the “Backup”.
When the file browser window pops up for, you can change the filename and choose the location to save the backup
file. Note that different web browser might handle this differently. If the operation is blocked due to the security
setting of the web browser, you should change the security setting temporarily to allow this operation to complete.
Restore Configuration
When restoring the configuration to a previous backup copy, you will need to specify the backup file you want to
restore to by selecting the “Browse” button in the Restore Configuration section of the web page. Then, select the
“Restore” button to start the process. The OBi device will automatically reboot, after the restoration is complete.
IMPORTANT Note:
All passwords and PINs are excluded from the backup file. Hence they will not be available to
restore. Call history is excluded from the backup, but can be saved as an XML formatted file separately from the Call
History web page.
Reset Configuration (to Factory Default)
The OBi device may be reset to factory default condition. Call history and various statistical information will be
removed at the same time. Resetting the device configuration should be used with
extreme caution
as the operation
cannot be undone. To do this you press the “Reset” button in the Reset Configuration section. A confirmation window
will pop up. The OBi device then proceeds to reset the configuration once you confirm that this is indeed what you
want to do. The OBi device will reboot automatically when factory reset is completed.
Service Provider Configuration Parameters
ITSP Profile
X
– General Web Page (
X
= A, B, C, D, E, F)
The following configuration parameters are available on this page.
Parameter
Description
Default Setting
General ITSP Settings (VoiceService.1.VoiceProfile.
k
.),
k
= 1 – 6 for X = A – F, respectively
Name
Human-readable string to identify the profile
instance. Maximum Length = 127 characters
SignalingProtocol
Choose among the following list of signaling protocols
for this ITSP:
SIP
Option
Description
Default Setting
Incl. Running Status
If checked, the value of all status parameters will be included in backup
file. Otherwise, status parameters are excluded from the backup
No
Incl. Default Value
If checked, the default value of parameters will be included in the
backup file. Otherwise, default values are excluded from the backup
No
Use OBi Version
If not checked, the backup file uses XML tags that are compliant with TR-
104 standard. Otherwise, the backup file will be stored in an OBi
proprietary format where the XML tags are not compliant with TR-104;
but the file size will be smaller and the file will be more readable
No