1 689 979 924N 26.11.07
83
15.
Error messages
If an error occurs on the test stand or if a not permissible mode
of operation is set, an error message appears at the indicator
instruments of the large measuring range and the indicator lights
are flashing.
The indicators move to a certain position from which a diagnosis
may be derived using the error list. The error message consists of
the left-hand and the right-hand indication.
Example:
Left-hand indicator instrument 1.0 kN (10 division marks)
Right-hand indicator instrument 1.5 kN (15 division marks)
The error message reads „10 15“.
On a scale with two measuring ranges, the smaller range applies,
e.g. BT 6xx 0-8kN.
If an LCD display (option) is installed, the error code is additionally
shown here.
Error messages with a „*“ can be cancelled by the customer by
means of the „STOP“ key (52) so that he may continue working.
15.1
Error in general
Error code 00 05 *
During the zero balance adjustment, the left or right touch roller
limit switch was closed.
Cause:
- Vehicle in roller set during zero balance adjustment.
- Connecting line between inductive sensor and switchbox
defective
- Inductive sensor defective
Error code 00 10 *
Test stand is set to RH/LH running operating mode and the speed
switch to 5 km/h.
Cause:
This mode of operation is only permissible for 2.5 km/h, since
this is an uncontrolled RH/LH running which must not be used
for passenger cars (5 km/h).
Error code 00 11 *
During the self-test, 1 hardware component could not be initiali-
zed on the CPU PCB A1.
Cause:
- Printed circuit board A1 defective.
Error code 00 20 *
If the brake force for a passenger car > 150 N and for a truck >
750 N increases within the last 2 seconds before reaching the
measuring range end value, the braking took place too quickliy
and the measurement is invalid.
Error code 00 22
When switching on the system, an error on the EEPROM is
detected.
Cause:
- After replacing the circuit printed board, the EEPROM does
not contain anly valid values.
Remedy:
- In the configuration menu step 59, accept and save basic
values.
Error code 00 23 *
Error when reading out the EPROM.
Cause:
- No EPPROM available
- EEPROM defective.
- Printed circuit board A1 defective.
Error code 00 24 *
Error when reading out the EPROM.
Cause:
- No EPPROM available
- EEPROM defective.
- Printed circuit board A1 defective.
Error code 00 25 *
Operator error at the remote control. An incorrect value has been
entered.
Error code 00 27 *
Timeout when writing the EPROM.
Cause:
- No EPPROM available
- EEPROM defective.
- Printed circuit board A1 defective.
Error code 00 29
System error
Error code 00 30 *
The measuring value has exceeded a maximum permissible
measuring value in the measuring range „passenger car“. If this
value is exceeded, the roller set is deactivated for safety reasons.
Cause:
- Inspection of a truck in the passenger car mode
Error code 01 01 *
Weight varies by more than 3%
Error code 05 00 *
Start-up locking protection or no turning signal from touch rollers
when activating the motors.
Cause:
- Vehicle brake not released
- Inductive sensor defective
- Printed circuit board A1 defective
Error code 05 30 *
When switching on the test stand, the left/right touch roller limit
switch was closed.
Cause:
- Vehicle in roller set when switching on
Error code 10 05
The key „STOP“ (52) was pressed during activation of the test
stand.
Error code 10 15 *
When switching on, the printer that has been entered into the
configuration menu is not recognized.
Cause:
- Printer incorrectly configurated
- Defective printer cable
- Printer not available
- Printer defective
Summary of Contents for BT 610
Page 4: ...4 26 11 07 1 689 979 924N ...
Page 5: ...1 689 979 924N 26 11 07 5 Deutsch ...
Page 49: ...1 689 979 924N 26 11 07 49 English ...
Page 94: ...94 26 11 07 1 689 979 924N ...