SENSOR TEST
General notes
Activating the sensor test: call parameter
Tools > Test > Sensor test
.
By means of the sensor test, you can check the function of each sensor:
[135] Display after calling „Sensor test“.
A
Sensor ID
B
Sensor name
C
Value
Analog values
• If the value shown on the printer display exceeds the range given in the chart below, the re-
spective sensor is possibly dirty and has to be cleaned (blow the dirt off with compressed air).
• Check the sensor function, e.g. by covering it. If the displayed value doesn´t change when the
sensor is covered, it is possibly not connected or defective.
General rule for all analog sensor values:
– Full light leads to values <= 10
– No light leads to values >= 220
• To sensors which function as a switch applies the following: Values between 10 and 220 mean
that the sensor is poorly set, dirty or close to the end of its life.
Digital values
Some sensors work digitally, what means that they don´t provide a value range, but the two values
„1“ or „0“.