Service manual
XLP 504 / XLP 506
05/2018 | 04
209
Malfunctions
8401 PDF417 Lines
Bar code PDF417: illegal number of lines.
Alter number of lines.
8402 PDF417 Columns
Bar code PDF417: illegal number of columns.
Alter number of columns.
8403 PDF417 Style
Bar code PDF417: incorrect style.
Alter style.
8404 PDF417 Command
Bar code PDF417: incorrect command.
Acknowledge by pressing the on-line button.
Check and alter commands.
8405 PDF417 Size
Bar code PDF417: incorrect size.
Alter size.
8406 PDF417 Details
Bar code PDF417: incorrect details.
Alter details.
8407 PDF417 Coding
Bar code PDF417: coding error.
Acknowledge by pressing key 4.
8500 Code 25Int len.
Bar code Code 25 Interleaved: input line too long.
Shorten input line.
8501 Postcode length
Bar code postcode: illegal data length.
Check length of the transmitted data and set it to the permitted length.
8600 EAN Length
Bar code EAN: illegal data length.
Check length of the transmitted data and set it to the permitted length.
8601 UPCE Numbers sys.
Error: First data character of the transmitted data is not 0 or 1.
Alter first data character to 0 or 1.
8705 IDM rows/columns
The input data does not match the given matrix or the number of rows/columns is invalid.
Change the number of rows/columns or the input data.