Service manual
XLP 504 / XLP 506
05/2018 | 04
213
Malfunctions
In this case, the network will not be initialised. To enable work with the network, a valid MAC ad-
dress must be programmed on the board. This can only be done by an authorized service techni-
cian or by the manufacturer.
Acknowledge the status message by pressing key 4. The printer will be starting, but cannot be
used with a network.
Contact the technical support for a new programming of the board´s MAC address.
If a new programming is not possible, exchange the CPU board.
9008 Powerfail signal
“Powerfail” is a signal at the power supply, which is normally activated for a short time, after the
printer has been switched off. It triggers the storing of parameter settings and counter values, using
the leftover of supply voltage.
The powerfail signal is already active after switching the printer on. The following causes are pos-
sible:
• Defektive power supply
• Defektive data cable
• Defektive board
Switch the printer off and on again. If the error occurs repeatedly:
Check the hardware (see above).
After acknowledging the message (pressing key 4), the printer works normal. But be aware that the
powerfail signal is deactivated, what means, that no parameter settings and counter values are
stored, when the printer is switched off.
9009 Temporary MAC
Temporary MAC address.
This error message is displayed, if the MAC address has the value
00.0a.44.00.00.00
. This MAC
address is used only during production.
Acknowledge the status message by pressing key 4. The printer will be starting and the network
can be used.
Contact the technical support for a new programming of the board´s MAC address.
If a new programming is not possible, exchange the CPU board.
9011 Load firmware for x
At least one external device has no valid (e.g. an incomplete) application program loaded. This is
the reason, why the device remains in the bootloading status and signalizes this status message.
„x“ can be one of the following module names:
• Feed driver
• Peripheraldriver
• Intern. rewinder
Load a valid application program.
9013 Head voltage
Faulty 5 V print head supply voltage. Possible causes are:
• Print head was connected to the wrong connector on the CPU board.
• Short circuit, possibly is the print head defective.
Check if the print head is connected to the correct connector on the CPU board. Change the con-
nector, if necessary.
Summary of Contents for XLP 504
Page 1: ...Edition 9 5 2018 Translation of original version SERVICE MANUAL XLP 504 XLP 506 Label printer ...
Page 2: ......
Page 238: ...Service manual XLP 504 XLP 506 05 2018 06 238 Appendix WIRING DIAGRAMS See next pages ...
Page 248: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...