Service manual
XLP 504 / XLP 506
05/2018 | 03
53
Service Mechanics
Installing the deflector shaft
Fasten the deflector shaft [83A] from the rear side
using two screws (2x Torx M4x16 [83B]).
Installing the cable harness
Only XLP 504 “basic” (XLP 504 “peripheral” comes
already equipped with the cable harness).
1. Remove the cover from the D-Sub installation
opening.
2. Remove the feed motor.
3. Feed the cable harness through the D-Sub installa-
tion opening [84A].
4. Fix the D-Sub plug with 2 hex bolts.
5. Install the cable [85A] underneath the motor fasten-
ing domes as shown [85 circle].
6. Feed the cable through the cable holder [86 circle].
7. Connect the cable.
See cabeling diagram, chapter
[83] Installing the deflector shaft (A)
[84] Feeding the D-Sub cable harness (A) through the opening.
[85] Cable installation behind motor (motor removed).
[86] Cable installation.
A
B
A
A
Summary of Contents for XLP 504
Page 1: ...Edition 9 5 2018 Translation of original version SERVICE MANUAL XLP 504 XLP 506 Label printer ...
Page 2: ......
Page 238: ...Service manual XLP 504 XLP 506 05 2018 06 238 Appendix WIRING DIAGRAMS See next pages ...
Page 248: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...