Service manual
XLP 504 / XLP 506
05/2018 | 09
147
Darkness
Print contrast for ZPL printjobs. This setting is modified by printjobs which contain print contrast in-
formation. The print contrast set by
Print > Print contrast
is not influenced by this setting
Label top
Label top offset (y-offet) in dots. Equals the parameter
Print > Y - Printadjust
, which will be ignored,
when ZPL printjobs are printed
Left Position
Left position offset (x-offset) in dots. Equals the parameter
Print > X-Druckversatz
, which will be igno-
red, when ZPL printjobs are printed
Error Indication
Selects the way, in which the printer responds in the event of error occuring during printing.
Error Checking
Enables or disables error checking, when the printer is handling print fields.
•
Yes
: Error checking is enabled
• No: Error checking is disabled
Resolution
Print resolution in dpi. A 200 Dpi graphic printjob can be printed with a 300 Dpi print head.
Setting range
Default setting
Step width
Easy Plug
[0...30]
15
1
--
Setting range
Default setting
Step width
Easy Plug
[-240...240] Dots
0
1
--
Setting range
Default setting
Step width
Easy Plug
[-9999...9999]
0
1
--
Settings
Default setting
Step width
Easy Plug
Low, High, Off
Off
--
--
Error
level
Setting
Off
Low
High
0
Ignore
Ignore
Ignore
1
Ignore
Ignore
Display-Anzeige
2
Ignore
Prompt user for action
Prompt user for action
Settings
Default setting
Step width
Easy Plug
Yes, No
Yes
--
--
Settings
Default setting
Step width
Easy Plug
200 Dpi, 300 Dpi
300 Dpi
--
--