Service manual
XLP 504 / XLP 506
05/2018 | 04
72
Service Electronics
Sensor connections
Schematic diagram for connectors CN905 to CN909 on the CPU board:
Lithium Battery
The CPU board used in the XLP 50x is equipped with a realtime clock, which keeps its setting, if
the printer is switched off. This is done by a lithium battery on the board.
The battery is
not rechargeable
!
The battery must be UL-listed!
Battery type
Panasonic CR2032 or an equivalent battery type.
Specifications
Battery replacement
1. Switch off the printer. Disconnect the power cord.
2. Take off the rear hood.
Prior to installation of the new battery: wipe the battery and the equipement terminal clean
using a dry cloth.
Ensure, that dust and other foreign substances will not cause shorting between the poles.
Pin
Belegung
1
Anode
2
Kathode
3
Kollektor
4
Emitter
1
2
3
4
WARNING!
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type recommended by the manufacturer.
Take care of the correct polarity when replacing the battery.
Discard used batteries according to the manufacturer´s instructions.
AVERTISSEMENT!
Il y a danger d´explosion s´il y a remplacement incorrect de la batterie.
Remplacer uniquement avec une batterie du même type ou d´un type recommendé par le
constructeur.
Mettre au rébut les batteries conformément aux instructions du fabricant.
Characteristic
Value
Nominal voltage
3 V
Nominal capacity
220 mAh
Continous standard load
0.2 A
Operating temperature
-30 bis +60 °C
Max. abnormal charging current
5.0 mA
[Tab. 11] Battery type CR2032 - specifications and dimensions.