Service manual
XLP 504 / XLP 506
05/2018 | 04
75
Service Electronics
XLP 504: OUTPUT STAGE BOARD M5A FOR STEPPER
MOTOR
Application notes
• Die Endstufe M5A wird als Endstufe für die Motoren der Optionen LTSA und TCS eingesetzt,
die nur für den XLP 504 vorgesehen sind
• Erforderliche Firmware-Version: mindestens 4.48
Checking the firmware version
Call
Info > System > Module FW. Vers. > Peripheraldriver
.
The firmware version of the installed peripheral output stage is displayed.
Updating firmware
Updating the driver firmware is done the same way as with the printer firmware:
See chapter
The following file is required:
M5A_xx_ALL_downloadfile.S3B
(for firmware version xx).
Connections, settings
[113] Connections of the output stage board M5A (A7579)
A
Mounting bracket
B
Jumper for setting the rotation direction (JP101)
C
Sensor connection
D
Jumper for setting the motor type (JP100)
E
Motor connector
F
Connector CPU board (data line)
G
Connector power supply
A
B
C
D
E
F
G
Summary of Contents for XLP 504
Page 1: ...Edition 9 5 2018 Translation of original version SERVICE MANUAL XLP 504 XLP 506 Label printer ...
Page 2: ......
Page 238: ...Service manual XLP 504 XLP 506 05 2018 06 238 Appendix WIRING DIAGRAMS See next pages ...
Page 248: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...