Service Mechanics
Replacing the ribbon core adapters
The ribbon core adapters ensure that the ribbon roll
holds firmly on the unwind or rewind mandrel. Each rib-
bon mandrel carries two different adapters [16C+D],
the inner one [16D] being additionally equipped with a
clamp spring. The procedure of exchanging the adapt-
ers is the same on both ribbon mandrels.
Tool
Screwdriver, medium size
Removing
1. Remove the lock washer [16A].
2. Remove the shim ring [16B] and the core adapter.
Installation
Perform the installation in the reverse order to the re-
moval. Note the following:
Turn the outer core adapters so that the wings [17A]
show in the same direction as those at the inner adapt-
er.
[32] Core adapters (C, D) at the ribbon rewind mandrel.
[33] Mind the position of the core adapters. The wings (A) must
show in the same direction at all three adapters.
A
B
C
C
D
A
Summary of Contents for XLP 504