Service manual
XLP 504 / XLP 506
05/2018 | 04
189
Malfunctions
1277 Wrong #!S..
Faulty Easy Plug code. Faulty use of the immediate command "#!S..". The specified parameter val-
ue exceeds the admissible value range (P, R).
Specify an admissible parameter value.
Please read the notes in chapter
1278 Wrong #!X..
Faulty Easy Plug code. Faulty use of the immediate command "#!X..". The specified parameter val-
ue exceeds the admissible value range (S, B, P).
Specify an admissible parameter value.
Please read the notes in chapter
1279 #!X wrong number
Faulty Easy Plug code. Faulty use of the immediate command "#!X..". The specified parameter val-
ue exceeds the admissible value range.
Specify an admissible parameter value.
Please read the notes in chapter
1282 Spooler FB > L
General software error, read chapter
1285 #!-comm. incorr.
Faulty Easy Plug code. Faulty use of the immediate command "#!..!. The specified letter is un-
known.
Specify an admissible letter.
Please read the notes in chapter
1290 Label limit
Faulty Easy Plug code. Value for x or y position exceeds the label limit.
Reduce the value for the x or y position.
Please read the notes in chapter
1291 Draw field
Faulty Easy Plug code. Function call, drawing object, unsuccessful.
Please read the notes in chapter
1300 Invalid Command
General software error, read chapter
1301 Table full
General software error, read chapter
1310 Wrong Field ID
The error can have several causes.
Please read the notes in chapter
1320 No Default Value
Faulty Easy Plug code.