Malfunctions
8900 Codablock columns
Bar code Codablock: illegal number of columns.
Correct number of columns.
8901 Codablock rows
Bar code Codablock: illegal number of rows.
Correct number of rows.
8902 Codablock softw.
General software error, read chapter
8903 Codablock infogr
Bar code Codablock: info not in line.
8950 Logo open
Failure when attempting to read a logo, which has previously been copied on RAM disk or on mem-
ory card (thus using Easy Plug command #DK).
Repeat loading the logo via #DK command.
In cases of continuous occurence of this error, please contact the technical support.
8951 File format
General software error, read chapter
8952 Not installed
General software error, read chapter
9000 Wrong errornum
General software error, read chapter
9001 Software Error
General software error, read chapter
9005 No print head
Print head could not be detected. Possible causes:
• Print head cable not connected
• Wrong print head type
• Defective print head cable
• Defective CPU board
• Print head cable plugged into wrong connector on the CPU board
Check print head cable, print head and CPU board and replace defective parts.
9007 Bad MAC Address
This error message is displayed, if an invalid MAC address is programmed to the CPU board. Valid
means, the MAC address matches the range
00.0a.44.xx.xx.xx
., which is reserved for NOVEXX
Solutions.