Service manual
XLP 504 / XLP 506
05/2018 | 09
145
EasyPlug errors
Handling of errors caused by faulty Easy Plug commands.
•
Tolerant handl.
: The label is printed, after the Easy Plug/Bitimage error was acknowledged.
•
Strict handling
: The Easy Plug command, which caused the error, is displayed after approx. 2
seconds in the lower display line. The displayed text is up to 30 characters long and is scrolled
automatically.
If a single character caused the error, this character is marked with „>> <<„ in the display text,
to facilitate the detection.
By pressing key 4, the display can be toggled between error message and Easy Plug command
text
After acknowledging the first occured Easy Plug error, the printjob and the spooler are deleted
(as by #!CA). This prevents the printing of labels with format errors.
Spooler mode
The operating mode of the spooler determines whether print series are processed individually, or
whether the spooler can receive print data when printing several series.
•
Mult. print jobs
: Multiple print series mode (the interface can receive data while the series is
being printed)
•
Single print job
: Single print series mode (the interface can only receive data after printing the
required number of labels of a single series)
StandAlone Input
Defines an interface for data input in standalone mode.
Interfaces are only selectable, if installed and not used by another function (e. g. as data inter-
face). If
Printer Language > Print interface
= „Auto negotiation“, all interfaces besides Com3 are blanked
out
•
None
: No data input via interface.
•
Serial Com1
: Com1 is activated for data input in standalone mode.
•
Serial Com3
: Com3 is activated for data input in standalone mode.
•
TCP/IP SOCKET
: Ethernet interface is activated for data input in standalone mode.
#VW/I Interface
Defines the output interface belonging to the Easy Plug command #VW/I.
Setting range
Default setting
Step width
Easy Plug
Tolerant handl., Strict handling
Tolerant handl.
--
Settings
Default setting
Step width
Easy Plug
Mult. print jobs, Single print job
Mult. print jobs
--
#PC1102
Settings
Default setting
Step width
Easy Plug
None, Serial Com1, Serial Com3,
TCP/IP SOCKET
None
--
Settings
Default setting
Step width
Easy Plug
Easyplug, Serial Com1, USB,
TCP/IP SOCKET, Serial Com3
Easyplug
--