Malfunctions
8302 Barcode checksum
Error during calculation of the bar code check sum.
Check transmitted data.
If the error continues to occur please contact the manufacturer. Send the transmitted Easy Plug
data.
8303 Bar code sample
Error during calculation of the bar code sample.
Check whether the transmitted data is permitted for the bar code type; if necessary alter the da-
ta.
8304 Bar c. plain-copy
Error during integration of the plain-copy line in the bar code sample.
Check whether the transmitted data is permitted for the bar code type; if necessary alter the da-
ta.
8305 Bar code print
Error during calculation of the bar code print image.
Acknowledge by pressing key 4.
Check whether the transmitted data is permitted for the bar code type; if necessary alter the da-
ta.
8306 Plain-copy len.
Illegal: bar code plain-copy line has more than 300 characters.
Reduce line length.
8307 Readline dist.
General software error, read chapter
8308 Bar code ratio
Illegal bar code ratio.
Select another ratio.
8309 Module range
Maximum range of the bar code module exceeded.
Reduce module range.
8310 Bar code element
Bar code element exceeds the maximum permitted size of 253 dots (21 mm).
Reduce size of the bar code element.
8311 Barcode table
General software error, read chapter
8400 PDF417 ECC
Bar code PDF417: incorrect ECC level (Error Correction Level).
Alter ECC level.