Service manual
XLP 504 / XLP 506
05/2018 | 03
42
Service Mechanics
Closing lever sensor
Testing the sensors: See chapter
Tools
• Torx screwdriver, size 10
• Side cutters
Removing
1. Remove screw [55B], take off the sensor [55A].
2. Open cable clamps, cut cable ties. Remove cable
from cable clamps.
3. Unplug end of cable from CPU board.
Installation
Perform the installation in the reverse order to the re-
moval. Note the following:
Connect the sensor to plug CN 907 [56A] on CPU
board.
Install the cable so that it does not contact any mov-
ing parts.
[55] Closing lever sensor (A).
[56] Connection from closing lever sensor to CPU board.
A
B
A