3.3.6 Oblique test
When carry out oblique test for foundation pile after flat test,
press Oblique button to enter into the interface as shown in Figure
4.11, select the section for oblique test.
1. Select oblique test section
Press view area in oblique test interface, a cursor line will
appear; use up and down buttons in floating toolbar to adjust the
position of cursor line and move it to proper height, press Upper and
Lower to terminate the defect area. Press Clear button to clear all
selected defect areas. Press Exit button to return to previous interface
(static collection interface, which is the interface before enter into
oblique test).
NOTE: Selected defect areas must appear in pair and
cannot be overlapped. Move cursor to the middle position of
defect area to change the upper limit or lower limit in this area.