Novatest S.r.l.
Manual for Multichannel Ultrasonic Pile Integrity Tester
136
5. Zero acoustic time
It refers to the acoustic time delay of ultrasound equipment and
transmitting and receiving the transducer system. It can be input
manually. Pressing Zero button to obtain the zero acoustic time
automatically by the zero set function. (Please refer to Section 3.6 for
details).
7.3 Start Test
7.3.1 Start sampling
Arrange one measuring line non-crack-across cracks and
several crack-across measuring lines at the object to be tested and
arrange the test points (the test points on across crack measuring lines
must be arranged symmetrically at both sides of the crack) at each
measuring line.
Use the signal line to link two planar transducers with the
transmitting and receiving channels of the instrument respectively
and couple the transducer at the two test points closest to the
measuring non-crack-across line on the object to be tested (the inner
edge of the transducer tangents the test point), and then press the
Sample button at the main interface to start continuous sampling