Novatest S.r.l.
Manual for Multichannel Ultrasonic Pile Integrity Tester
93
Figure 4.18 Wave train graph
3.4.4 Data list
Press Data button to switch to the view of Data list and display
all test point data of current profile, as shown in Figure 4.19. Press
single-channel waveform area to switch profile.
Press data list area and the selected rows display in yellow, the
waveforms of selected test point of current profile display in
single-channel waveform area (If there is not data at a certain height,
“--” will display in table and corresponding single-channel waveform
area will not display waveform).
The right side of data list is single-profile curve graph, press a
certain position in curve graph to automatically jump to the data line
where this test point is located. The right side of curve graph displays
information such as average value and critical values of each acoustic