Novatest S.r.l.
Manual for Multichannel Ultrasonic Pile Integrity Tester
172
F1.3
Ultrasonic method for testing
uncompacted area and cavitations
F1.3.1 Preparation before test
1. Division of labor
Divide the testers at first, one person takes charge of general
instrument operation and on-site record, one person for placing
transmitting transducer and one person for receiving transducer.
2. On-site data and information collection
1) Project name and design, construction, and entrusting units
names.
2) Test purpose and requirements;
3) Type and specification of concrete raw material;
4) Template type, concrete forming date and pouring and
curing conditions;
5) Structural member dimension, reinforcement construction
drawing or reinforcement concealment drawing;
6) Appearance quality and problem of structural member.
3. Position(test position) selection for defect test
Determine the position for defect test (called “test position” for
short) according to test requirements and operation conditions.
When test uncompacted areas and cavitations, the tested position