3.4.1 Terminology
1) Dynamic sampling: It refers to the process of continuously
and repeatedly transmitting, collecting, processing,
interpreting and displaying waveform and acoustic
parameter.
2) Dynamic waveform: It refers to the continuously refreshing
waveform in single- channel waveform range on screen in
dynamic sampling.
3) Static waveform: It refers to the static waveform in
single-channel waveform range on screen when stop
sampling.
4) Head wave (preliminary wave): The first wave crest or
trough of waveform received by instrument.
5) Noise range: Manual-set noise range in dynamic sampling,
it is used to distinguish waveform from noise; any
waveforms with amplitude not exceeding such range is
considered as noise.
6) Threshold value: It is one of the automatic judging criteria
of head wave, only the waveform exceeding threshold
value line will be possibly judged as head wave; the two
dotted lines above and below base line, as shown in Figure