Novatest S.r.l.
Manual for Multichannel Ultrasonic Pile Integrity Tester
139
7.3.5 Test the next object
After testing an object, a new object shall be created before
moving to the next (press New button behind the Component name
in the parameter setup dialog box).
Before creating a new object, check whether the current object
data has been modified but not saved and prompt to save it. When
creating a new object, eliminate the current object data to maintain
the last parameter setting. (for example the starting point spacing and
step spacing).
7.4
Test point data list area
The Test point data list area is used to display the original testing
data(including spacing test and acoustic time) and intermediate result
(calculating the crack depth) of the testing points on the current crack,
as shown in Figure 7.4. Press a data line in the area, and it will turn
to the current test point (showed in yellow) and the waveform area
shows the test point waveform. If the crack depth is less than 0, it
will display “---”.