Novatest S.r.l.
Manual for Multichannel Ultrasonic Pile Integrity Tester
116
saved in this folder. As of creating folders, if project with identical
name has existed, then give prompt “this project has existed, please
input project name again.”
2
)
Select tested project
Press
T
button behind pull-down list box of Project box to list
all tested projects, select one to save its pile data files in this project.
2. New Object
After completing of test on one object, to test on next object,
may button New button behind the Component Name to pop up
character soft keyboard, input name of object to be tested and
complete new object procedure. Object data tested previously will be
saved automatically prior to new object being set up.
Integrity of current object data (whether test points have been
tested or not) will be checked prior to new object operating, if
incomplete, then corresponding prompt information will be
displayed.
3. Row number
Row number refers to total quantity of grid transverse row
arranged on object to be tested, which input range is from 1 to 50.
4. Column number
Column number refers to total quantity of grid vertical line
arranged on object to be tested, which input range is from 1 to 50.