Novatest S.r.l.
Manual for Multichannel Ultrasonic Pile Integrity Tester
99
2
)
Select tested project
Press
T
button behind pull-down list box of Project box to list
all tested projects, select one to save its pile data files in this project.
2. New object
When move to test the next object after the last one, press New
button next to the Component name to pop up the character soft
keyboard and input name of object to be test to complete the new
object. The last tested object will be saved automatically.
3. Number of Test Regions
Number of test regions refers to the total number of test regions
arranged on the object to be detected, and its input range is from
1
∼
50.
4. Number of Test Points
Number of test points refers to the total number of test points
arranged in every test region, which generally is 3 points or 5 points.
When choosing Jiangsu curve, the number of test points is 5 and that
of other curves is 3.
5. Test Distance
Test distance refers to the distance of dissemination of acoustic
wave, i.e. the centre-to-centre spacing between transmitting and
receiving transducers, which range is 1
∼
5000mm. As to strength test
in combined method, diagonal test, all of angel test and flat test are
available. The test distance of diagonal test refers to the distance