Novatest S.r.l.
Manual for Multichannel Ultrasonic Pile Integrity Tester
132
soft keyboard for entering characters, input project name to
create a subfolder with such name, and all data files of following
tested objects will be saved in this folder. When create a new
folder, if the project with the same name has existed, it will
prompt “This project has existed already, please input the project
name again”.
2
)
Select tested project
Press
T
button behind the pull-down list box of Project to
list all tested projects under the current project, select one to
save all following data file in this project.
2. Create new object
When move to the next object after the completion of the last,
press the New button behind the component to clean the data of the
current object and create a new crack test file to conduct the test of
the new object. The tested data will be saved automatically before
creating new object.
3. Starting point spacing
The starting point spacing is the distance between the
transmitting of the first test point and the inner edge of the receiving
transducer, generally 100mm.
4. Step spacing
The relative moving distance of transmitting and receiving
transducer is generally 50mm.