Novatest S.r.l.
Manual for Multichannel Ultrasonic Pile Integrity Tester
50
3.10 System Setup
The system setup function is used to set instrument information
and public parameter.
Press System Setting button in startup interface to pop up
dialogue box as shown in Figure 3.9. This dialogue box includes
three property pages of General parameter, Instrument information
and Internet parameter, as shown in Figure 3.13, 3.15 and 3.16
separately. The default of each parameter is the value which has been
set last time.
After have set all parameters, press OK button to validate all
sets and return to startup interface, press Cancel button to invalidate
all sets and return to startup interface.
In the interface of system setup, press Default button, the
dialogue box of “whether restore factory setting or not?” will appear,
press Yes button to restore all parameters to factory setting or No
button for not.
In system setup interface, press Versions button to pop up
dialogue box of version information for checking software, hardware,
core or firmware, etc.