Novatest S.r.l.
Manual for Multichannel Ultrasonic Pile Integrity Tester
38
Press Search button for automatic sampling and searching the
head wave of current waveform.
4
)
Adjustment of base line
Press Wave
↑
and Wave
↓
buttons to adjust base line position
upward or downward;
5
)
Adjustment of noise range width
Press Th and Threshold– buttons to increase or
decrease threshold value for determining head wave;
6
)
Close operation panel
Press any areas outside of single-channel waveform range to
close operation panel.
3.4.3 Static waveform operation
In the state of static waveform, press a certain waveform in
single-channel waveform range to use this channel as current channel,
one transverse cursor and one vertical cursor will appear in waveform
range, and operation panel as shown in Figure 3.6 will pop up under
current waveform.