Novatest S.r.l.
Manual for Multichannel Ultrasonic Pile Integrity Tester
69
Figure 4.4 General parameter
1. Instrument system delay
System delay input into the instrument. After have input a value
in “Pipe 1-2”, if the option “All profiles of the same” is selected,
values in other pipes are as same as this value. If not selected, value
of each pipe may be changed separately.
2. Selection of technical specification
After have selected corresponding test procedure, data will be
real-time analyzed and processed according to the procedure in test.
3. Acoustic speed limit
Whether limit the range of acoustic speed when search head