![Nortel 1002rp Maintenance And Diagnostics Download Page 57](http://html1.mh-extra.com/html/nortel/1002rp/1002rp_maintenance-and-diagnostics_1707105057.webp)
January 2007
Using serial port diagnostic tools
1002rp Server Maintenance and Diagnostics
57
TSTSERIO internal loopback diagnostic subtests
The following internal loopback subtests are available for the
TSTSERIO command. For each of these tests, the communications
resource must be available.
Table 10: TSTSERIO internal loopback subtests
/P:comport
Required
Specifies the symbolic port name
assigned to the port you want to test.
/S:subtstname
Optional
Specifies a TSTSERIO subtest. See
the following table for a description of
the available subtests.
/L:loops
Optional
Specifies the number of times (up to a
maximum of 65 535) to execute the
requested test. The default number of
tests is 1. A value of 0 infinitely loops
until you enter Ctrl+C.
Subtest
name
Description
idat
Internal data bus loopback
imsr
Internal modem status register
baud
Internal data bus loopback at various baud rates
word
Test 5-, 6-, 7-, and 8-bit data lengths
stop
Test 1, 1.5, and 2 stop bits
pari
Test odd/even parity
fifo
Test that device can operate in fifo mode
Flag
Requirement
Description
Summary of Contents for 1002rp
Page 6: ...Standard 1 11 6 CallPilot...
Page 14: ...Contents Standard 1 11 14 CallPilot...
Page 30: ...Troubleshooting your CallPilot system Standard 1 11 30 CallPilot...
Page 92: ...Using CallPilot Manager to monitor hardware Standard 1 11 92 CallPilot...
Page 108: ...Using CallPilot system utilities Standard 1 11 108 CallPilot...
Page 138: ...Replacing basic chassis components Standard 1 11 138 CallPilot...
Page 156: ...Replacing media drives Standard 1 11 156 CallPilot...
Page 190: ...Replacing voice processing boards Standard 1 11 190 CallPilot...
Page 216: ...Index Standard 1 11 216 CallPilot...
Page 217: ......