![Nortel 1002rp Maintenance And Diagnostics Download Page 105](http://html1.mh-extra.com/html/nortel/1002rp/1002rp_maintenance-and-diagnostics_1707105105.webp)
January 2007
Using CallPilot system utilities
1002rp Server Maintenance and Diagnostics
105
For tower and rackmount CallPilot servers, DSPs reside in MPB96 and
MPB16-4 boards and MPC-8 cards. For 1002rp servers, DSPs are
distributed as follows:
MPB96 board has 12 DSP sections embedded on board
One MPB16-4 board consists of two embedded DSPs and up to four
MPC-8 cards.
Each MPC-8 card contains a single DSP.
DS30X links
In the DS30X link pane, each DS30 row represents a separate DS30X
link (also referred to as a DS30 link). Each box in the row represents one
DS30X channel.
The DS30X links connect the CallPilot server to the MGate card
(NTRB18CA) in the Meridian 1 switch or Succession 1000
*
system.
For the 1002rp server, the DS30X link to the switch is supported by the
connection of the server to the switch backplane.
T1 Links
In the T1 link pane, each row represents a T1 link. Each box in the row
represents one DS0 channel.
System Info tab
Figure 12 on page 106 shows an example of the System Info tab.
Summary of Contents for 1002rp
Page 6: ...Standard 1 11 6 CallPilot...
Page 14: ...Contents Standard 1 11 14 CallPilot...
Page 30: ...Troubleshooting your CallPilot system Standard 1 11 30 CallPilot...
Page 92: ...Using CallPilot Manager to monitor hardware Standard 1 11 92 CallPilot...
Page 108: ...Using CallPilot system utilities Standard 1 11 108 CallPilot...
Page 138: ...Replacing basic chassis components Standard 1 11 138 CallPilot...
Page 156: ...Replacing media drives Standard 1 11 156 CallPilot...
Page 190: ...Replacing voice processing boards Standard 1 11 190 CallPilot...
Page 216: ...Index Standard 1 11 216 CallPilot...
Page 217: ......