![Nortel 1002rp Maintenance And Diagnostics Download Page 171](http://html1.mh-extra.com/html/nortel/1002rp/1002rp_maintenance-and-diagnostics_1707105171.webp)
January 2007
RAID operations
1002rp Server Maintenance and Diagnostics
171
Synchronizing RAID drives
To synchronize the RAID after a successful
operation
1
Without shutting down the server, right-click the first drive on
Channel 2.
Example:
(0) A1-2-Failed.
2
From the pop-up menu select Rebuild. When the Rebuild is
complete, repeat the process for the remaining two drives on
Channel 2.
Result:
When all three drives are rebuilt:
a.
All three drive status’ changes to ONLINE.
b.
The color of the icons changes to green.
c.
The alarm should stop beeping unless it was temporarily
silenced.
Note:
The process can take up to 1 hour. DO NOT shut down the
machine before the rebuild is complete.
3
Monitor the rebuild by opening the Windows MegaRAID console.
To synchronize the RAID after an unsuccessful
operation
If the operation has failed, the system needs to be returned to the original
configuration.
1
Reboot the CallPilot server.
2
Press Ctrl+M when prompted while the server is booting.
Summary of Contents for 1002rp
Page 6: ...Standard 1 11 6 CallPilot...
Page 14: ...Contents Standard 1 11 14 CallPilot...
Page 30: ...Troubleshooting your CallPilot system Standard 1 11 30 CallPilot...
Page 92: ...Using CallPilot Manager to monitor hardware Standard 1 11 92 CallPilot...
Page 108: ...Using CallPilot system utilities Standard 1 11 108 CallPilot...
Page 138: ...Replacing basic chassis components Standard 1 11 138 CallPilot...
Page 156: ...Replacing media drives Standard 1 11 156 CallPilot...
Page 190: ...Replacing voice processing boards Standard 1 11 190 CallPilot...
Page 216: ...Index Standard 1 11 216 CallPilot...
Page 217: ......