January 2007
Replacing basic chassis components
1002rp Server Maintenance and Diagnostics
135
JP5—Disarming no power in the bottom bay
If you are operating with one power supply, you can disable sensing of
no power from the bottom power supply. To do this, install a jumper on
jumper block 1, JP5.
Ensure that the functioning power supply is installed in the upper power
bay.
JP4
Not used.
JP3—LED display
Install a jumper on jumper block 1, JP3, to configure the alarm board to
send alarm signals to the full array of LEDs. This is the default setting
and the required setting for normal server operation.
If this jumper is not installed over both pins, the alarm board does not
send the correct format of signals to the front panel display.